L & L Sales and Service, Inc.
 
PATZ Electric Shredder Pumps
Patz 1512 Manure Pump

Patz 1512 Manure Pump

Storing manure has become attractive and profitable. The key to successful management of manure is an efficient system of moving the manure to storage.

The Patz Model 1512 Manure Pump is designed to handle manure ranging in consistency from free-flowing liquid to slurry with fine-cut bedding. Liquid manure has up to 5% solids, and slurry manure has 4% to 15% solids.

The optional in-line valve provides a positive shutoff to prevent backflow.

Saving time as well as manure nutrients is easy with the Patz Model 1512 Manure Pump. Manure drops into hopper from your gutter cleaner. Or scrape to the hopper. A plunger forces manure through PVC pipe to storage.

The Patz manure pump is designed for easy maintenance. Both the plunger and plunger sleeve can be removed for inspection. An optional in-line valve installs in the 12-inch or 15-inch PVC pipe buried up to 8 feet deep as a shutoff valve. Install if a backflow is possible. An optional flapper valve fits the end of the PVC pipe in the holding area to prevent manure from flowing back into the pipe.

Note: Manure too dry to flow may require the addition of water. Manure pumps are not designed for pumping box stall manure, ensilage, hay, wood shavings, lime, sand, crushed rock, etc.

  • Drive Unit uses 10 hp. electric motor. Plunger driven through triple V-belt, double #100 roller chain-and-sprocket drive unit. Large 2-1/2 inch and 1-3/4 inch shafts plus high quality bearings assure durable operation. (Guard removed for viewing.)
  • 180 (U.S.) gallon hopper can be filled with gutter cleaner or scraper. Constructed of 1/8-inch steel. Approximately 3 ft. by 7 ft. opening at top.
  • Plunger sleeve with internally functioning plunger mounts in 1/4-inch thick steel chamber embedded in concrete. Plunger and plunger sleeve may be removed for easy servicing without concrete breakup.
  • One-way valve in plunger opens to fill plunger sleeve on backward stroke. On forward stroke, valve closes and the plunger forces the manure toward storage facility.
  • Fiberglass cover guard does not rust and provides long service life.
  • Plunger Size: 7 x 15 in.
  • Stroke Lengths: 20 in., 17 in. and 14 in.
  • Hole Size for Pump Installation: 5 ft. wide x 14 ft. long x 7 ft. 3in. deep (approximately).
  • Floor Space Required for Pump: 3 ft. 2 in. x 11 ft. (approximately).
  • Weight: 2,350 lb. (approximately).
  • Safety Railing: Standard equipment.
  • Pipe Length: Recommended maximum length of pipe with no elbows, 150 ft. Deduct 5 ft. for each 22-1/2 elbow used and 10 ft. for each 45 elbow. Up to 90 of elbows may be used in one installation.
  • Pipe Size: Choose 15" or 12" PVC pipe.
  • Storage Height (Head): Maximum storage height (head) is 25 ft. This is measured from center line of pipe at manure pump to top of manure in storage area.
Patz 3333 Manure Pump

Patz 3333 Manure Pump

The Patz Model 3333 Multi-Use Vertical Pump provides high performance for quick transfer of liquid wastes including:
-Dairy waste water
-Manure separator liquid residues
-Hog manure
-Rain or flood water

  • The tapered-bore drive pulley mounts to a 1-1/8-inch (29 mm) drive shaft with a greaseable flange bearing at the top of the drive tube. A lip seal below this bearing keeps contaminants out of the drive tube. The drive tube is filled with oil to lubricate the support bearings inside the tube and the bottom bearing.
  • Easy access to oil reservoir. End guessing - inspect oil level conveniently in transparent oil line at top of pump. A large fill hole allows easy access for adding oil to the drive tube. Patz recommends using a non-detergent oil.
  • High-volume delivery. The voluted design of the impeller housing and the curved blades increase pumping efficiency at a rate of around 500 gallons per minute.
  • Lower repair costs with abrasion-resistant steel impeller housing and shredder plate.
  • Protection against bearing contamination. The lower bearing's oil-bath chamber has four seals to keep contaminants out.
  • Bearing seals can be purged every 8 hours thanks to a grease line from the seal pack to the top of the pump.
  • Clogging prevented and positive input provided. Shear plate located close to the impeller to help prevent clogging and provide positive input.
  • Shear plate has two legs to help support pump off the floor of the pit.
  • Impeller transition area features beefed-up steel for long life.
  • Light weight and high-strength discharge pipe. Our 3-inch (76 mm) diameter Schedule 80 PVC discharge pipe reduces the weight of the pump for easy handling while providing a high-strength, low-wear, low-friction discharge tube. Various lengths available from 3 to 12 feet.
  • All stainless steel hardware below the liquid line for long life and easy servicing.
  • Attaching eye located on top of the pump allows easy insertion and removal of the unit in the pit with a tractor loader, skid-steer loader or winch.
  • A steel plate is included as standard equipment to allow you to precisely position the pump to match your pit depth. Plate can be lagged to a concrete pad or curb.
  • Pump available in various lengths to fit pit depths of 3 to 12 feet (1 to 3.6 m).
Patz 4444 Manure Pump

Patz 4444 Manure Pump

This versatile pump handles limited fibrous waste. The impeller blades' swept-back design increases pumping efficiency for high-volume flow through the 4-inch (101.6 mm) steel tube.

  • Pumping capacity up to 1,580 gals./min (5,981 liters/min.).
  • Available in lengths to fit your application: 6 ft. (1.8 m), 8 ft. (2.4 m), 10 ft. (3.0 m), and 12 ft. (3.6 m)
  • A 16-inch (40.6 cm) Impeller for added capacity.
  • Variable agitation capacities with a standard dual agitation system.
  • Abrasion-resistant steel in high wear areas for longer life
  • Versatile - can be used in a variety of applications: Agitate a pit, Move from short-term to long-term storage, Load tankers/spreaders and separators, Transfer wastewater
  • Tapered-bore drive pulley mounts to a 1-3/4 inch (44.5 mm) drive shaft with a greaseable flange bearing at the top of the drive tube.
  • Easy access to oil reservoir. End guessing! Inspect oil level conveniently in transparent oil line at top of pump. A large fill hole allows easy access for adding oil to the drive tube. Patz recommends using a non-detergent oil.
  • High-volume delivery. The voluted design of the impeller housing and the curved blades increase pumping efficiency.
  • Protection against bearing contamination. The lower bearing's oil-bath chamber has 3 seals to keep contaminants out. No sleeve bearings to wear out fast.
  • Clogging prevented and positive input provided. Shear plate located close to the impeller to help prevent clogging and provide positive input.
  • Lifting loops located on top of the pump allows easy insertion and removal of the unit from the pit with a tractor loader, skid-steer loader or winch.
  • A steel mounting plate is included as standard equipment to allow precise positioning of the pump to match the pit depth. Plate can be lagged to a concrete pad or curb.
  • Pump available in various lengths to fit pit depths of 5 ft. 6 in. (1.7 m) to 12 ft 10 in. (3.9 m).
Patz 6000E Manure Pump

Patz 6000E Manure Pump
  • A stationary base secured to manure pit is standard on the 6000E Pump.
  • Equipped with a two-point tractor hitch for easy insertion and removal from pit for service.
  • Match your pit depth with choice of four pump lengths: 6, 8, 10 and 12 feet (1.83, 2.44, 3.05 and 3.66 m). Large U-bolts allow the frame to be adjusted up or down for precise placement.
  • Twin motor belt drive systems are easier on the upper drive shaft and bearings.
  • Get better pit clean-out by agitating with a nozzle which can be rotated horizontally.
  • Remove clumps of straw with chopping action over impeller shredder plate.
  • When there is no crusting or settled solids, pump liquid manure with low-investment pump or add options as needed.
  • Save time when agitating, transferring, and loading due to swept-back impeller blades for high-volume pumping up to 2,500 gallons (9,463 liters) per minute-during agitation and 2200 gallons (8,328 liters) per minute during loading.
  • Get high load-carrying capacity and long service life from tapered roller bearings in oil bath chamber protected by three seals.
  • Unique plumbing system eliminates need to enter pit. Ask dealer for details.
  • Lower repair costs with impeller housing of abrasion-resistant steel in high-wear areas.
  • End guessing about oil level. Inspect oil level conveniently in transparent oil line at top of pump.
  • Horsepower Requirements: Twin 15, 20, 25, or 30 HP, 3-phase motors.
  • Ask for more information about remote agitation/storage systems.